Ed, replace Q4851 (200168 / NO ECG) on pincushion board. -Clint Happy Thanksgiving & God Bless Us All Clint Hamilton, Owner http://OrpheusComputing.com http://ComputerHardware-ConsumerElectronics.com sales@xxxxxxxxxxxxxxxxxxxx Fax: 209-882-9602 TechAssist Administration http://tech-assist.org techassist@xxxxxxxxxxxxx 4orpheus@xxxxxxxxxxxxx (alternates) orpheuscomputing@xxxxxxxxx (PLEASE include our previous correspondence if replying to this email!!) ----- Original Message ----- From: "Tel-Tek Electronics" <teltek@xxxxxxxxxxx> To: "AAAA TECH-ASSIST" <techassist@xxxxxxxxxxxxx> Sent: Friday, November 23, 2001 10:10 AM Subject: [TechAssist] RCA CTC177BH2 Set came in No Channels, just snow. Replaced eprom. Which fixed that problem. But the picture is too wide, only one Ch. digit showing on screen. Found CR403 shorted and replaced. C407 looked OK, (not bubbled), but replaced anyway. Also changed Regulator STK730-010, didn't make any difference. Have checked setting on Eprom for Horizontal width, setting OK, but when changing value of parameter, does not do anything. What have I missed. TIA. -Ed- teltek@xxxxxxxxxxx TEL-TEK ELECTRONICS. ================================= Help make your TechAssist database better! Submit your fixes here: http://circuitwork.com/techassist/tip/#tips ================================= To UNSUBSCRIBE your email address, click here: mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe ================================= Help make your TechAssist database better! Submit your fixes here: http://circuitwork.com/techassist/tip/#tips ================================= To UNSUBSCRIBE your email address, click here: mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe