Replace both shorted parts, then replace the 47uf or 39uf cap that is
located between the SMPS output and the SMPS drive IC.

Damon Brunger
damon101@xxxxxxxxxxxxxx
Telrad Electronic Services
Ft Wayne, IN 46815
----- Original Message -----
From: "Bill S" <billans@xxxxxxxxxxxx>
To: <techassist@xxxxxxxxxxxxx>
Sent: Monday, November 26, 2001 11:24 PM
Subject: [TechAssist] RCA CTC169BG 35"


>
> Hi all;
> We have this unit  where another 'retired tech' got into this but did not
> have enough muscles and or bench space to go any further with this.
> The surge resistor is opened as well as the degauzing thermistor opened
> up.....   They then gave this unit for me to finish...... The regulator is
> shorted.
>
> Is this the unit that needs the regulator updated modification kit????  If
> so .. What is the number of the kit..
>