Where is C4402? I found a C402 and a C402K on the board. The C402K is a blue cap with a value of 0.056F at 400 volts, whereas C402 is a 2.2uF electrolytic. C4102/104/108 all test good, so should I still replace them? Kevin Wilks Kevin's TV & Video Repair Penticton BC Canada kevintv@xxxxxxx -----Original Message----- From: techassist-bounce@xxxxxxxxxxxxx [mailto:techassist-bounce@xxxxxxxxxxxxx] On Behalf Of tvservice Sent: Friday, October 08, 2004 6:59 AM To: techassist@xxxxxxxxxxxxx Subject: [TechAssist] Re: RCA CTC169BA, G35300WK, 35" monster, HOT shorted C4402 is open or c4102 or c4108 has changed value replace C4402 and cr4402, c4102, c4108 and maybe c4104 cr4118 should be replaced for reliability Robert tvservice@xxxxxxxxxxxxx H & H Electronics Inc ----- Original Message ----- From: "Kevin" <kevintv@xxxxxxx> To: "TECH-ASSIST" <techassist@xxxxxxxxxxxxx> Sent: Friday, October 08, 2004 2:23 AM Subject: [TechAssist] RCA CTC169BA, G35300WK, 35" monster, HOT shorted > The HOT, D1885 is shorted on this CTC169 chassis. I pulled the chassis > because this set is too large to bring into the shop. The flyback rings > good, and I can find no bad connections or bad electrolytic caps. Are > there any tips for the cause of the shorted HOT? Thanks. > > Kevin Wilks > Kevin's TV & Video Repair > Penticton BC Canada > kevintv@xxxxxxx > > > > > ------------------------------------------------------------------------ -- --- > Lost Password: > http://www.tech-assist.org and select "Login Problems?". > Email Archives: > //www.freelists.org/archives/techassist/ ------------------------------------------------------------------------ ----- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/ ----------------------------------------------------------------------------- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/