[TechAssist] Re: RCA 60" PTK195 (no model) dead again 3rd time

Don't need chipper check on the ptk195
press menu and hold then press and release power and volume up then release
menu
press volume up to 76 then channel up P1 is 1st error, channel up P2 is 2nd
error channel up P3 is 3rd error code
after reading codes press volume up or down to zero each code for next time.
press power to escape menu

Robert
tvservice@xxxxxxxxxxxxx
H & H Electronics Inc
Dallas, TX

----- Original Message ----- 
From: "Phil Bader" <tjanphyl@xxxxxxxxxxxxxxx>
To: <techassist@xxxxxxxxxxxxx>
Sent: Wednesday, November 26, 2003 4:41 PM
Subject: [TechAssist] Re: RCA 60" PTK195 (no model) dead again 3rd time


> The shop does not have a chipper check.As far as I know thats the only way
to see
> them. Am I correct?
> They may have to carry it to me, as i do.
> Phil
>
> tvservice@xxxxxxxxxxxxx wrote:
>
> > What are the error codes?
> >  I have had the sound decoder IC U11600 give intermittent dead
> >
> > Robert
> > tvservice@xxxxxxxxxxxxx
> > H & H Electronics Inc
> > Dallas, TX
> >
> > ----- Original Message -----
> > From: "Philip Bader" <tjanphyl@xxxxxxxxxxxxxxx>
> > To: <techassist@xxxxxxxxxxxxx>
> > Sent: Tuesday, November 25, 2003 5:03 PM
> > Subject: [TechAssist] RCA 60" PTK195 (no model) dead again 3rd time
> >
> > > Assisting another shop.
> > > Originally dead. Replaced the flyback. The HOT was OK (funny)
> > > Ran several weeks OK. Dead again. Replaced fly and HV splitter. Came
up
> > > and ran OK.
> > > Carried the chunk to the house, installed it. Had no sound there, but
> > > customer kept it as a monitor until tech could get back and see about
> > > the sound.A week or so later (last night) tech went over and cured the
> > > "no sound" issue.Audio output IC on main board needed resoldering. (he
> > > had removed it during testing). Now good pix and sound.
> > > Ran all night good,customer turned it off, went to bed.
> > > This morning tried to turn on: Only a "tic". Dead again.
> > > First, wierd it ran a week OK, resolder sound amp, dead overnight,
> > > secondly, the HOT was never bad. Still the original HOT is in it.
> > > I think this tech is chasing his tail with some obscure crack in the
> > > board, or maybe an intermittant HOT?
> > > Anyone see this?
> > > A parts used OEM RCA.
> > > Phil Bader
> > > --
> > > Philip Bader
> > > Jan Phyl TV Inc. (estab. 1976)
> > > 3420 Recker Hwy. Winter Haven, Fl. 33880
> > > Fax (863) 299-8821
> > > email: tjanphyl@xxxxxxxxxxxxxxx
> > >
> > >
> >
****************************************************************************
> > *
> > > Lost Password:
> > > http://www.tech-assist.org  and select "Login Problems?".
> > > Email Archives:
> > > http://www.freelists.org/archives/techassist/
> > >
> >
> >
****************************************************************************
*
> > Lost Password:
> > http://www.tech-assist.org  and select "Login Problems?".
> > Email Archives:
> > http://www.freelists.org/archives/techassist/
>
> --
> Philip Bader
> Jan Phyl TV Inc
> 3420 Recker Hwy
> Winter Haven, Fl. 33880
> Fax: 863-299-8821
> "consumer electronics service since 1977"
>
>
>
>
****************************************************************************
*
> Lost Password:
> http://www.tech-assist.org  and select "Login Problems?".
> Email Archives:
> http://www.freelists.org/archives/techassist/
>

*****************************************************************************
Lost Password:
http://www.tech-assist.org  and select "Login Problems?".
Email Archives:
http://www.freelists.org/archives/techassist/

Other related posts: