[TechAssist] Re: Philips 27PS55S321

  • From: <support@xxxxxxxxxxxxxxxxxx>
  • To: <techassist@xxxxxxxxxxxxx>
  • Date: Fri, 26 Dec 2003 21:14:45 -0500

Paul,
From Tech Repair CD:


Magnavox\27PS55S321 27T800\Shutdown (into protect) with no symptom 
shown\Adjustment of Sg2 (master screen
on LOT) may resolve but symptom may return\\27T800 \The LOT (flyback) 5445. 
Several returned samples have
been discovered with unstable/intermittent Sg2 controls.\Monitoring the Sg2 
voltage may provide proof of
this as the cause of protection\\\\\\\

Jeff Dougherty
Intrepid Video TV/VCR
263 S Front St
Steelton PA 17113
fax...717-564-4952
www.intrepid-video.com www.tech-repair.net

----- Original Message -----
From: "Paul" <dntwntv@xxxxxxxxxxxxx>
To: <techassist@xxxxxxxxxxxxx>
Sent: Friday, December 26, 2003 2:54 PM
Subject: [TechAssist] Philips 27PS55S321


Hv comes up wave form looks normal at collector of HOP xstr. Plays for about 5 
seconds and shuts down.
Have pulled the pic tube socket. The B+ is 127v at the HOP xstr. The scvreen 
voltage is only 6v. Bad IHVT?
Screen voltage winding shorted ? It is not burning. Maybe isn't on long enough 
to burn?       Paul

Paul ,B
Central TV&Video
Grover Beach Ca.

*****************************************************************************
Lost Password: