Seems to me that 165V is normal for a 195 in standby mode. Have you 
tried starting the set with the splitter disconnected?

John Myers
Myers TV Service Co.
376 E. State St.
Alliance, OH 44601

Voice / Fax: 330-821-6545
Myers_tv_b@xxxxxxxxxxxxx
http://www.myerstv.net

Work as if you were to live a hundred years,
Pray as if you were to die tomorrow.
                           Ben Franklin




Jim Myers wrote:

>HOT was shorted, sub HOT allowed chassis to start up but with a loud 
>snap and shorted the sub HOT. Now with a new FBT it shuts down due to 
>the high B+ but does not short the sub HOT. Intention is to not install 
>the new OEM HOT until the high B+ is fixed.
>Does anyone have a tip?
>