[TechAssist] Re: PANASONIC CT-36SX12F CHASSIS AP382

If you have to unplug and plug back in to get it to turn on again the 
protect circuit has been tripped, the amplitude and waveshape of the HO 
collector pulse and the B+ to the flyback is where to start. Also check 
regulation of the B+ by turning up the line voltage on your variac.

The Old Master Technician
********************************
Since 1972                     *
Jim Myers                      *
Telrad Electronics             *
Fort Wayne Indiana             *
********************************


R&S ELECTRONICS wrote:
> TV plays for a while (30min to an hour) than goes off (its dead set) the only 
> way to start is to un[lug the set and plug it back in TV comes on fine. The 
> cycle keeps on going .
> Pls let me know if anyone has seen this problem or what to look for?
> Anybody has a schematic for it.
> Thanks
> R&S Electronics,PA
> TEL:(717)532-6312
> Email:rselect@xxxxxxxxxxxx
> -----------------------------------------------------------------------------