No the CS35601 will not bypass properly. Try to fix if you can. If you bypass this board your video level will be low and it will cause unstable sync. If the customer is not using any video inputs and only using the RF input , you can raise the video level adjustment slightly to compensate the weak sync after bypassing the PIP but this only works on RF input. Tony Saracco TCS ELECTRONICS Gilberts , IL 60136 847-426-5880 tcselectronics@xxxxxxxxx ----- Original Message ----- From: "alltv" <alltv@xxxxxxxxxxxxx> To: "Techassist@xxxxxxxxxxxxx" <techassist@xxxxxxxxxxxxx> Sent: Wednesday, December 17, 2003 12:10 AM Subject: [TechAssist] Mitsubishi CS35601 PIP problem Hi All I just want to know if anyone can tell me if the PIP can be bypass. Pip number 930B552 0,1,2 Thanks in Advance email to : alltv@xxxxxxxxxxxxx Ken Dinckan All Tv&Appliance Service 2747 Roosevelt Street Suite B Carlsbad CA, 92008 Phone : (760)434-1131 **************************************************************************** * Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/ ***************************************************************************** Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/