[TechAssist] Re: Mitsubishi CS35601 PIP problem

  • From: "tony saracco" <tcselectronics@xxxxxxxxx>
  • To: <techassist@xxxxxxxxxxxxx>
  • Date: Wed, 17 Dec 2003 08:40:27 -0600

No the CS35601 will not bypass properly. Try to fix if you can. If you
bypass this board your video level will be low and it will cause unstable
sync. If the customer is not using any video inputs and only using the RF
input , you can raise the video level adjustment slightly to compensate the
weak sync after bypassing the PIP  but this only works on RF input.

Tony Saracco
TCS ELECTRONICS
Gilberts , IL 60136
847-426-5880
tcselectronics@xxxxxxxxx
----- Original Message -----
From: "alltv" <alltv@xxxxxxxxxxxxx>
To: "Techassist@xxxxxxxxxxxxx" <techassist@xxxxxxxxxxxxx>
Sent: Wednesday, December 17, 2003 12:10 AM
Subject: [TechAssist] Mitsubishi CS35601 PIP problem


Hi All
I just want to know if anyone can tell me if the PIP can be bypass. Pip
number 930B552 0,1,2
Thanks in Advance

email to : alltv@xxxxxxxxxxxxx
Ken Dinckan
All Tv&Appliance Service
2747 Roosevelt Street Suite B
Carlsbad CA, 92008
Phone : (760)434-1131

****************************************************************************
*