Hi All I was sevicing a Mits Projo today and found many shorts on secondary of SMPS transformer. Shorts to ground that is....so I isolated the transformer and found all the pins shorted together all but two. When I checked the schem. it clearly shows three seperate and isolated windings. (secondary) Pins 10 and 11 test as one winding. That's OK Has anybody else found this to be faulty?? Must not be common!! Did I miss anything else? This is the short version of the story. PS The set would not fire up only click twice. No blown fuses!! 8 here I Had changed the main regulator, Opto Isolator, and 130 V reg... no fix... All coments welcome. TIA Warren Campbell Campbell,s TV & Appliances Cannington On ***************************************************************************** CHECK OUT THE NEW CHATROOM! Just login and click on chat! http://www.tech-assist.org/secure/tip/main.htm The Tech Address Book: http://www.tech-assist.org/secure/tip/contact.htm Add a Repair Tip Here, or Change/Remove your Email Address: http://www.tech-assist.org/secure/tip/main.htm Lost Password: http://www.tech-assist.org and select "Lost your Login Info?". Email Archives: //www.freelists.org/archives/techassist/