Doyle: Here are some common ones for that chassis. Obviously the STR is an issue, and experience says that R407 should be replaced if it has not been already. --------------------------------------------------------------- Text pasted from WinSTIPS 2.0 http://www.servicesoftware.com --------------------------------------------------------------- PHILIPS TV L4 Int Oper May Run Cold But Turn Off/When On Relay Chatters Only Ic430 Str30130 (Eccg1777) --------------------------------------------------------------- PHILIPS TV L4 Power - Comes On For One Minute,Goes Off Replace Str 30130, Put Jumper From Str To R 431 --------------------------------------------------------------- PHILIPS TV L4 Power Up Inop. Relay Clicks 47k-1/2w Resistor Feeding B+ To Horiz Drive Circuit Open (May Be R407) --------------------------------------------------------------- Best regards, --== Paul ==-- ---------- Paul R. Gendreau, Jr. Tel: 207-490-1835 Fax: 207-490-1893 Email: Paul@xxxxxxxxxxxxxxxxxxx http://www.servicesoftware.com -----Original Message----- From: techassist-bounce@xxxxxxxxxxxxx [mailto:techassist-bounce@xxxxxxxxxxxxx]On Behalf Of Tranbarger Electronics Sent: Saturday, November 24, 2001 6:48 PM To: TechAssist@xxxxxxxxxxxxx Subject: [TechAssist] Magnavox chassis # 13L404-OOEE This set shuts down after warmed up/wont stay on till cooled down.. R410 5W 390 ohm running too hot to touch, but checks ok. Thermistor R400 too hot to touch as well. All test point voltages check ok. Anyone got any ideas? --no schematic Thanks, Doyle ================================= Help make your TechAssist database better! Submit your fixes here: http://circuitwork.com/techassist/tip/#tips ================================= To UNSUBSCRIBE your email address, click here: mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe ================================= Help make your TechAssist database better! Submit your fixes here: http://circuitwork.com/techassist/tip/#tips ================================= To UNSUBSCRIBE your email address, click here: mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe