had 2 like that,keeps cycling on and off. FLYBACK
barrystv@xxxxxxx
Barrys TV
Ottawa Canada
----- Original Message ----- 
From: "Keith Trumbla" <keith@xxxxxxxxxxxxxxxxxx>
To: <techassist@xxxxxxxxxxxxx>
Sent: Thursday, May 20, 2004 1:34 PM
Subject: [TechAssist] KV27V15 Weird PS problem


> Q601 Q602 shorted. Changed or checked the following: H.O.T , soldered
driver xformer, all vdr's, small tant caps 609-612, T502, R644, R607. When
you plug the set in, the relay (not degauss relay) cycles about 1 second
on/off. Disconnected input to FBT as well. Help !!
> Keith Trumbla
> www.bemelectronics.com