This unit was dead ei. no video on screen. Hear relay click at power-on.
Diode shorted on -160V supply, secondary off fly. Located on main board
directly below the shield on the CRT board, also look for trace of smoke
coming for electro cap, same location.]
Sorry I didn't get location numbers but got sidetracked by the phone.
Al G
Al's TV-Electronics
Pembroke Ont.