[TechAssist] Re: KDS VS21e EVOKD-2100K

  • From: "Technotronic Dimensions" <steve@xxxxxxxxxxxxxxxxxxxxxxxxxxx>
  • To: <techassist@xxxxxxxxxxxxx>
  • Date: Fri, 23 Jul 2004 17:22:42 -0400

Bill:

         The LED Change from Blink to Solid means Signal is detected. So
problem likely not on CRT PCB.

        If you Power off both the Test Signal and the Monitor, then Repower
the Monitor First, let the heaters Warm up, and power up the Test Signal
Source, What does it do? Do you hear HV Come up briefly with a Possible
Horiz Line visible on the screen for a Split Second? Try that test at
640-480, then with it set to 800-600.  Also, what are you using for the Test
Signal Source?

Steve Hearns
Technotronic Dimensions, NY [USA]
WWW.TECHNOTRONIC-DIMENSIONS.COM
1-877-817-9885 (Voice / Fax Toll Free - US Only)


----- Original Message ----- 
From: "Bill Grabowski" <bgrabowski@xxxxxxxxx>
To: <techassist@xxxxxxxxxxxxx>
Sent: Friday, July 23, 2004 5:14 PM
Subject: [TechAssist] Re: KDS VS21e EVOKD-2100K


Yes I tried diffrent refresh rates. I started monitor and have green
pilot light with amber blink every second or so but no click when I
inject the signal.Then green pilot stays lit with no amber. It does
click when I change from 640+480 to 800+600. Thanks for the help.

Bill Grabowski
Triangle Appliance
Kenosha,WI  53142

Technotronic Dimensions wrote:
> Did you try different Refresh rate Settings? Start off on 640-480, listen
> for a CLICK when you apply the Signal with Power already on - let us know
if
> you hear a CLICK.
>
> Steve Hearns
> Technotronic Dimensions, NY [USA]
> WWW.TECHNOTRONIC-DIMENSIONS.COM
> 1-877-817-9885 (Voice / Fax Toll Free - US Only)
>
> ----- Original Message ----- 
> From: "Bill Grabowski" <bgrabowski@xxxxxxxxx>
> To: "techassist" <techassist@xxxxxxxxxxxxx>
> Sent: Friday, July 23, 2004 3:00 PM
> Subject: [TechAssist] KDS VS21e EVOKD-2100K
>
>
> Would any tech have the schematics for this KDS model VS21e its my
> second request. Any help would be appreciated. Have changed
> flyback,HOT,and 2 burnt 1k resistors and need some help with why the
> filaments are lit but no HV. This is my last monitor. Thanks!!
>
>                                                         Bill

-- 
*****************************
Bill Grabowski
Triangle Appliance
Kenosha,Wi 53142
262-694-6500
262-694-6523 fax
bgrabowski@xxxxxxxxx
*****************************


----------------------------------------------------------------------------
-