[TechAssist] Hitachi 50UX8B in shut down. D912 protect diode flashing, FIX
- From: Phil Bader <tjanphyl@xxxxxxxxxxxxxxx>
- To: "techassist@xxxxxxxxxxxxx" <techassist@xxxxxxxxxxxxx>
- Date: Thu, 31 Mar 2005 10:53:31 -0500
Submitted by local shop.
Powered on this set, smelled something like a HV arc.
Pico fuse E994 open
The +120VDC indicator LED D940 was unlit.
LED indicator diode for "protect-mode" D912 was flashing.
HOT good.
Cause was a small blue 2KV scan disc cap hidden under the larger ones
had arced internally: C707 "102 / 2KV".
C707 replaced, E994 replaced fixed set.
Phil Bader
--
Philip Bader
Jan Phyl TV Inc. (estab. 1976)
3420 Recker Hwy. Winter Haven, Fl. 33880
Fax (863) 299-8821
email: tjanphyl@xxxxxxxxxxxxxxx
-----------------------------------------------------------------------------