35" Toshiba 1995 model. I thought there was another problem with the set after I repaired it, but after hooking cable up, TV stayed on without turning off. Kevin Wilks Kevin's TV & Video Repair Penticton BC Canada kevintv@xxxxxxx -----Original Message----- From: techassist-bounce@xxxxxxxxxxxxx [mailto:techassist-bounce@xxxxxxxxxxxxx] On Behalf Of Ed Gaidies Sent: Thursday, December 04, 2003 11:56 AM To: techassist@xxxxxxxxxxxxx Subject: [TechAssist] Re: Daewoo TV DTQ-29S1FCN CN2001 - Shutdown Kevin; Never seen a Toshiba do that. Some Emerson and Sanyo do...but not Toshiba. -Ed- Ed Gaidies Tel-Tek Electronics. Ontario-Canada teltek3@xxxxxxxxxxxx -----Original Message----- From: techassist-bounce@xxxxxxxxxxxxx [mailto:techassist-bounce@xxxxxxxxxxxxx] On Behalf Of Kevin Sent: December 4, 2003 1:54 PM To: techassist@xxxxxxxxxxxxx Subject: [TechAssist] Re: Daewoo TV DTQ-29S1FCN CN2001 - Shutdown Toshiba TV's will turn off after 15-20 minutes (I forget which) when there is not signal present. Good for the old days when TV stations actually went off the air to a snowy picture! Bad for a tech trying to test TV's without a signal. This sounds like what this TV is doing. Kevin Wilks Kevin's TV & Video Repair Penticton BC Canada kevintv@xxxxxxx -----Original Message----- From: techassist-bounce@xxxxxxxxxxxxx [mailto:techassist-bounce@xxxxxxxxxxxxx] On Behalf Of David Lessard Sent: Thursday, December 04, 2003 9:08 AM To: techassist@xxxxxxxxxxxxx Subject: [TechAssist] Re: Daewoo TV DTQ-29S1FCN CN2001 - Shutdown Bill, Thanks for the extra information, I will check out some of those other components you speak of in that service bulletin. I forgot to mention that when this TV does shutdown it is not necessary to unplug the AC to get it to reset, simply, I just hit the switch and ON it comes again. Also, I should note that I was testing this TV without a signal, no cable, no composite video inputted via RCA, just that blue startup screen. I hooked cable to the TV about an hour ago and it's still running, weird. Is it possible that the micro shuts down this TV if no signal is sensed after 15 minutes; I only state this because this TV was shutting down after the same amount of time transpired each and every time? This was after the new parts were installed. If it doesn't shut down for the rest of the day I'm convinced this may be the case. Again thanks, I'll let you all know what goes on with this one, and if in the meantime anyone has additional input, please share your thoughts. David Lessard Alexandria Electronics 50 Harrison Street Alexandria, Ontario K0C-1A0 mr_fixit@xxxxxxxxxxxx -----Original Message----- From: techassist-bounce@xxxxxxxxxxxxx [mailto:techassist-bounce@xxxxxxxxxxxxx] On Behalf Of Premium Technologies Sent: Thursday, December 04, 2003 11:27 AM To: techassist@xxxxxxxxxxxxx Subject: [TechAssist] Re: Daewoo TV DTQ-29S1FCN CN2001 - Shutdown Dave, Usually the replacement of C404, with a 160/3.3 solves a common intermittent shutdown and the resistor across the HOT the thermal runaway per bulletin. But this problem may have damaged regulator(s) or supports in that circuit - to the point that resistors may have changed in value. The remainder of that bulletin suggests replacement of Q805 (Kse3203), Q803 (Ksc2500), Q804(Kse13009), R818 (.33-1w), R806 (390k-1/2w), R812 (100-1/4w). The resistors only as needed, but I usually just replace them anyway. And the regulators can be substituted... Hope this helps. Bill William Rayburn, CET NESDA Member Premium Technologies PO Box 442 Long Beach, WA. 98631 (360) 642-4993 Phone (815) 425-8530 Fax ----- Original Message ----- From: "David Lessard" <mr_fixit@xxxxxxxxxxxx> To: <techassist@xxxxxxxxxxxxx> Sent: Thursday, December 04, 2003 7:56 AM Subject: [TechAssist] Daewoo TV DTQ-29S1FCN CN2001 - Shutdown > Hi Fellows, > > This TV was serviced by another shop for a shutdown problem that occurs > after 15 minutes of operation, they never fixed the problem and charged > the customer. I've read the emails, changed C404 (to a 3.3uf), added the > HOT modification (33ohm B-E), and even changed some other questionable > capacitors, still the problem remains. What should be the +B at TP10? I > read something somewhere, I think in the TechAssist archive, regarding > D401 (9.1V zener) off ABL line on flyback. What else should I be looking > for? I don't have a service manual. Thanks in advance. God Bless America > (North & South). > > David Lessard > > Alexandria Electronics > 50 Harrison Street > Alexandria, Ontario > K0C-1A0 > > mr_fixit@xxxxxxxxxxxx > > > ************************************************************************ **** * > Lost Password: > http://www.tech-assist.org and select "Login Problems?". > Email Archives: > //www.freelists.org/archives/techassist/ ************************************************************************ ***** Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/ ************************************************************************ ***** Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/ ************************************************************************ ***** Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/ ************************************************************************ ***** Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/ ***************************************************************************** Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/