Phil,
I had this very same problem with a CTC 187 chassis. Don't know if it will
be of any help on the CTC197 or not. Check to see if the HOT runs hotter
than normal to the touch, if it does I had to replace Horiz. Driver
Transformer (#215541) and C4306 (#188594) to solve shorting of HOT. Remember
these part #'s are for a CTC187 chassis.

                                                      Dan Webster
                                                      Webster's TV
                                                      Shullsburg, Wi.
----- Original Message -----
From: <Philstv@xxxxxxx>
To: <techassist@xxxxxxxxxxxxx>
Sent: Saturday, November 17, 2001 8:18 AM
Subject: [TechAssist] CTC197 - Repeated failure of HOT (C5148)


> Hi All. I had this set in some weeks ago. I replaced the HOT (C5148) and
the
> fly which I had to wait 4 months to get. The set came back dead again. I
> replaced the shorted HOT and it played for about 20 minutes and shorted
> again. Anybody had this problem?
>
> Phil - Phil's TV
>
>
> *****************************************