[TechAssist] Re: CTC 169 PG projection

  • From: armando guerra <birdie@xxxxxxxxxxxxx>
  • To: techassist@xxxxxxxxxxxxx
  • Date: Thu, 20 Nov 2003 10:36:39 -0700

Sounds like the reg B+ is running too high.Check the lytics around the reg ic
u4101.
Check C4102,4104,and C4108.They will probably read a high esr.
Mando
Birdie's TV & Electronics
Casa  Grande, AZ

Barry Thompson wrote:

> Hi All: Unplug HV anode from splitter and the high voltage comes up a way to
> high and then shuts down. Any ideas? Thanks Barry