Sounds like the reg B+ is running too high.Check the lytics around the reg ic u4101. Check C4102,4104,and C4108.They will probably read a high esr. Mando Birdie's TV & Electronics Casa Grande, AZ Barry Thompson wrote: > Hi All: Unplug HV anode from splitter and the high voltage comes up a way to > high and then shuts down. Any ideas? Thanks Barry > barrystv@xxxxxxx > Barrys TV > 613 224 3406 > Ottawa.Canada. > > ***************************************************************************** > Classifieds! Buy or Sell! > http://sell.tech-assist.org > The Tech Address Book: > http://www.tech-assist.org/secure/tip/contact.htm > Add a Repair Tip Here, or Change/Remove your Email Address: > http://www.tech-assist.org/secure/tip/main.htm > Lost Password: > http://www.tech-assist.org and select "Lost your Login Info?". > Email Archives: > //www.freelists.org/archives/techassist/ ***************************************************************************** Classifieds! Buy or Sell! http://sell.tech-assist.org The Tech Address Book: http://www.tech-assist.org/secure/tip/contact.htm Add a Repair Tip Here, or Change/Remove your Email Address: http://www.tech-assist.org/secure/tip/main.htm Lost Password: http://www.tech-assist.org and select "Lost your Login Info?". Email Archives: //www.freelists.org/archives/techassist/