[TechAssist] Re: APEX TV AT2402/chassis 10c1(s)

Check the cathode voltage on the green, then check it at the crt board with
the crt disconnected, if it stays the same your crt output is bad, if it
shoots up to 140-180v then you have an HK short, easily remedied by
Warrantied CRT or heater isolation device.

----- Original Message -----
From: "JOHN E. CARR" <CARR142@xxxxxxxxxxxxxxxx>
To: "Topics of interest to consumer electronics repair professionals"
<CONSUMERELREPAIR-L@xxxxxxxxxxxxxxxxxxxx>
Cc: <techassist@xxxxxxxxxxxxx>
Sent: Sunday, September 29, 2002 1:29 AM
Subject: [TechAssist] APEX TV AT2402/chassis 10c1(s)


>
>   This set made in April 2002, powers up with a green screen with retrace
> lines. I am hoping that it's not a
> H-K short. Does anyone with experience with this model, and know another
> reason for this symptom?
> Everything else is working fine on this set.
>
> Thanks,John Carr