[SI-LIST] stitched via shielding
- From: "Denomme, Paul S." <Paul.Denomme@xxxxxxxxxxxxxx>
- To: si-list@xxxxxxxxxxxxx
- Date: Thu, 27 Mar 2003 12:10:05 -0500
Hi All,
I am looking to shield a trace using stitched vias. What is the general
practice for stitching vias around a trace in order to obtaining shielding
from the rest of the system?
Here is my scenario:
I have .2mm wide 10Ghz signal trace going down a PWB. The nearest trace
running parallel to it is 0.2mm and the edge to edge distance of the traces
are 0.9mm. I will have stitched 0.3mm DIA ground vias located directed
between the two traces. What would the center to center spacing for the
vias need to be to virtually contain the 10GHz signal?
In practice I have seen via stitching rules of Lambda/20, and I have heard
of people using Lambda/30. This is not a production board, but a test
vehicle, so I am looking for what people are using today that helped them
obtain acceptable results.
Regards,
Paul S. Denomme
Design Engineer
Viasystems
804-226-5155
804-226-5193 (Fax)
------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
or to administer your membership from a web page, go to:
http://www.freelists.org/webpage/si-list
For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
List archives are viewable at:
http://www.freelists.org/archives/si-list
or at our remote archives:
http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
http://www.qsl.net/wb6tpu
Other related posts: