[SI-LIST] s2ibis2 extreme currents
- From: "Eric Steimle" <steimle@xxxxxxxxxxxxx>
- To: <si-list@xxxxxxxxxxxxx>
- Date: Wed, 16 Jun 2004 09:55:54 -0400
I've been trying for a few weeks to get some decent IBIS models from our
hspice decks. I'm working on a single tristate driver, with 3.3V I/O
and 1.8V core. I finally have something that looks reasonable but when
running it through the golden parser (actually Hyperlynx's Visual IBIS
editor check), I get "Extreme currents present in TYP GND_Clamp VI
Curve" messages. Now I look in the file and I see the extreme currents
start at around 3.7V in the pullup section and around -0.9V in the
GND_CLAMP section. These currents are in the 70A and -90 Amp and
higher ranges respectively
Does anyone have any experience with these kind of results? Am I doing
something wrong or is this something I'm supposed to know to fix
manually? I'm a little new at this model conversion stuff so any advice
would be appreciated.
Thanks.
Eric
------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
or to administer your membership from a web page, go to:
http://www.freelists.org/webpage/si-list
For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
List FAQ wiki page is located at:
http://si-list.org/wiki/wiki.pl?Si-List_FAQ
List technical documents are available at:
http://www.si-list.org
List archives are viewable at:
http://www.freelists.org/archives/si-list
or at our remote archives:
http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
http://www.qsl.net/wb6tpu
- Follow-Ups:
- [SI-LIST] resend: s2ibis2 extreme currents
- From: Ingraham, Andrew
Other related posts:
- » [SI-LIST] s2ibis2 extreme currents
- [SI-LIST] resend: s2ibis2 extreme currents
- From: Ingraham, Andrew