[SI-LIST] output signal degradation of cmos inverter driving a RC line
- From: "praveen_vrec_123" <praveen_vrec_123@xxxxxxxxxxx>
- To: si-list@xxxxxxxxxxxxx
- Date: Thu, 31 Mar 2005 10:10:24 -0000
hi friends,
I am driving a RC line with cmos inverter at
few mega hertz(using pspice), when i am appending the
RC line i am getting good output of cmos inverter, but
when i use a rc line, the signal is totally degrading.
i think it is due to low output capacitance of cmos
inverter , Am i right?. if so, what would be the
remedy?.plz i require ur help in this regard.
praveen
------------------------------------------------------------------