Paul: There is a bug in the ibischk3 code used by the Visual IBIS Editor concerning the reported percentage values. This is being fixed. However, the ERROR is correct and indicates that the Waveform table amplitudes do not match up with the I-V tables (above a 10% mismatch) for the given load. (The file and complete set of messages needs to be examined to be eliminate other possible factors such as strong non-monotonic data.) Some vendors choose to rescale the IBIS model data to make it work, while others will reject the model. The best solution is to get a good model with consistent information. Bob Ross Mentor Graphics Paul Fernando wrote: > > Does anyone know what this means & how to resolve it? Its produced when I > check an ibs file on Innoveda's Visual IBIS editor. > Thanks. > Paul > > ERROR - Model driver: The [Rising Waveform] > with [R_fixture]=500 Ohms and [V_fixture]=0V > has TYP column DC endpoints of 0.01V and 1.20v, but > an equivalent load applied to the model's I-V tables yields > different voltages ( 0.00V and 1.45V), > a difference of 54208654.45% and 17.00%, respectively. > ------------------------------------------------------------------ To unsubscribe from si-list: si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field or to administer your membership from a web page, go to: //www.freelists.org/webpage/si-list For help: si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field List archives are viewable at: //www.freelists.org/archives/si-list or at our remote archives: http://groups.yahoo.com/group/si-list/messages Old (prior to June 6, 2001) list archives are viewable at: http://www.qsl.net/wb6tpu