[SI-LIST] Re: [ibis-macro] IBIS model of drifferential driver with programmable multi-tap preemphasis
- From: "Muranyi, Arpad" <Arpad_Muranyi@xxxxxxxxxx>
- To: <ibis@xxxxxxxxxxxxxx>, <si-list@xxxxxxxxxxxxx>
- Date: Wed, 22 Jul 2009 07:53:31 -0700
Nitin,
If you have access to the stimulus, you could pull this off
with the Driver Schedule or even without it, but that would
be a semi official IBIS solution because it may not work in
all tools. For example, if you do it with the HSPICE B-element,
you could make a B-element for each stage of your buffer,
and then make a special stimulus generator which reproduces
the bit pattern dependent waveforms for the input to each
B-element (buffer stage). This way the stages of your buffer
would still be IBIS models, but the relationship between them
would be outside the IBIS world.
Another way to do it would be to use the *-AMS extensions of
IBIS. This way you could make a completely official model
for the entire buffer. However, not all IBIS tools have
implemented the *-AMS extensions of IBIS, although there are
several tools with Verilog-A support which may be sufficient
for what you want to do.
I hope this helps.
Arpad
===============================================================
-----Original Message-----
From: ibis-macro-bounce@xxxxxxxxxxxxx
[mailto:ibis-macro-bounce@xxxxxxxxxxxxx] On Behalf Of Nitin Kumar
CHHABRA
Sent: Wednesday, July 22, 2009 7:14 AM
To: ibis@xxxxxxxxxxxxxx; si-list@xxxxxxxxxxxxx
Cc: vishrant.goyal@xxxxxx; nitin.chhabra@xxxxxx; nitin.gupta@xxxxxx
Subject: [ibis-macro] IBIS model of drifferential driver with
programmable multi-tap preemphasis
Hi experts,
We want to develop the IBIS model for a differential driver with pre
emphasis .
The driver has three tap with programmable pre emphasis options.
Does anyone came across such IBIS or could provide some IDEA how to
proceed for the same.
Using Driver Scheduling, we are able to make model for first tap pre
emphasis buffer.
But we cannot accommodate the second and third tap options as they
require previous bit histories.
with regards,
Nitin
---------------------------------------------------------------------
IBIS Macro website : http://www.eda.org/pub/ibis/macromodel_wip/
IBIS Macro reflector: http://www.freelists.org/list/ibis-macro
To unsubscribe send an email:
To: ibis-macro-request@xxxxxxxxxxxxx
Subject: unsubscribe
------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
or to administer your membership from a web page, go to:
http://www.freelists.org/webpage/si-list
For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
List technical documents are available at:
http://www.si-list.net
List archives are viewable at:
http://www.freelists.org/archives/si-list
or at our remote archives:
http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
http://www.qsl.net/wb6tpu
Other related posts: