[SI-LIST] Re: What will happen if differential channel is not symmetric?
- From: Istvan Novak <istvan.novak@xxxxxxx>
- To: piyush bhatt <piyush.nithmr@xxxxxxxxx>
- Date: Sat, 25 Jul 2009 16:54:17 -0400
Hi Piyush,
For that operating frequency, though eventually the necessary frequency
band of the model
is determined by the signal's rise time, you should be able to get a
good start by TDR-ing
a sample if you get one. You can then put together a simple model to
match the TDR
response and use that model in the simulations.
Best regards,
Istvan Novak
SUN Microsystems
piyush bhatt wrote:
> Hi
>
> I need to simulate one net thru a connector .Vendor told us that they
> will provide us with models.But now our gerber release date is near
> and electrical models are not in sight.
> Can we take some approximation based upon pitch , mating hieght of
> connector etc.Max freq of operation is 170 mhz
>
>
> regards
> Piyush
>
------------------------------------------------------------------