Hi Chetan,
IBIS models accounts for high/low temperatures in the "min" and "max"
data values. In the same way, they account for the variations of the
supply voltage and the fabrication process.
That is, the I-V and V-T tables have:
1) a "typical" column, whose data are extracted from a buffer in typical
PVT (process/voltage/temperature) conditions;
2) a "max" column, whose data are extracted from a buffer in the fast
PVT (process/voltage/temperature) conditions (e.g., max temperature,
fast process and high supply level, or whichever mix of these conditions
is fastest);
3) a "min" column, whose data are extracted from a buffer in the slow
PVT (process/voltage/temperature) conditions (e.g., max temperature,
fast process and high supply level, or whichever mix of these conditions
is slower).
Thus, you just need to set your preferred EDA tool in order to simulate
with the set of data you want.
Hope it helps,
Luca
On Thu, 27 Mar 2003 11:29:09 +0530
"Chetan Jadhav" <chetan@xxxxxxxxxxxxxxxxxxxxxxx> wrote:
>
> Hi experts,
>
> I want to do SI simulation of my design at various temperatures.
>
> The IBIS models of the devices specify temperature ranges as 0 to 100 degree
> C and a typical value of 50 degree C.
> My knowledge is, the VI and VT curves of the devices are specified at 50
> degree C.
>
> How can I specify board and device temperatures in Cadence Spectra Quest??
>
> Even if there is a way, will the SI tool really scale the VI curves with
> specified temperature??
>
> Regards,
> Chetan
>
>
> ------------------------------------------------------------------
> To unsubscribe from si-list:
> si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
>
> or to administer your membership from a web page, go to:
> http://www.freelists.org/webpage/si-list
>
> For help:
> si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
>
> List archives are viewable at:
> http://www.freelists.org/archives/si-list
> or at our remote archives:
> http://groups.yahoo.com/group/si-list/messages
> Old (prior to June 6, 2001) list archives are viewable at:
> http://www.qsl.net/wb6tpu
>
--
Luca Giacotto <lgiacott@xxxxxxxxx>
------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
or to administer your membership from a web page, go to:
http://www.freelists.org/webpage/si-list
For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
List archives are viewable at:
http://www.freelists.org/archives/si-list
or at our remote archives:
http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
http://www.qsl.net/wb6tpu
- Follow-Ups:
- [SI-LIST] Re: Temperature variable in SI simulation
- From: Chetan Jadhav
- References:
- [SI-LIST] SI/EMC Job Openings
- From: 설병수
- [SI-LIST] Temperature variable in SI simulation
- From: Chetan Jadhav
Other related posts:
- » [SI-LIST] Temperature variable in SI simulation
- » [SI-LIST] Re: Temperature variable in SI simulation
- » [SI-LIST] Re: Temperature variable in SI simulation
- » [SI-LIST] Re: Temperature variable in SI simulation
- » [SI-LIST] Re: Temperature variable in SI simulation
- [SI-LIST] Re: Temperature variable in SI simulation
- From: Chetan Jadhav
- [SI-LIST] SI/EMC Job Openings
- From: 설병수
- [SI-LIST] Temperature variable in SI simulation
- From: Chetan Jadhav