Ravinder,
The Minimum Coupling Length isn't the only setting you can change that
will affect the reported crosstalk. What is your goal?
Aubrey Sparkman=20
Enterprise Engineering Signal Integrity Team
Dell, Inc.=20
Aubrey_Sparkman@xxxxxxxx=20
(512) 723-3592
-----Original Message-----
From: si-list-bounce@xxxxxxxxxxxxx [mailto:si-list-bounce@xxxxxxxxxxxxx]
On Behalf Of Ravinder.Ajmani@xxxxxxxxxxxxxx
Sent: Wednesday, December 28, 2005 6:39 PM
To: si-list@xxxxxxxxxxxxx
Subject: [SI-LIST] Selection of Minimum Coupled Length in Cadence
SPECCTRAQuest
Hi SI Experts,
My question pertains to the use of Cadence SPECCTRAQuest software for
performing crosstalk simulations.
The Default setting of Minimum Coupling Length is 300 mils, and I have
been using 200 mils coupling length for my simulations. However, I have
observed that when there are short length bends in the net (say when the
net travels around a via), these short lengths are treated as separate
sections of the net (Cline segments). If these sections are smaller
than 200 mils then they are not included in the coupling calculation.
Recently while simulating a design, I reduced the coupling length to 50
mils. This resulted in fourfold increase in the crosstalk.
I would like to know if such phenomenon has been observed by other users
too, and what is the coupling length they use in their simulations.
Thanks.
Regards, Ravinder
Server PCB Development
Hitachi Global Storage Technologies
Email: Ravinder.Ajmani@xxxxxxxxxxxxxx
------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
or to administer your membership from a web page, go to:
http://www.freelists.org/webpage/si-list
For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
List FAQ wiki page is located at:
http://si-list.org/wiki/wiki.pl?Si-List_FAQ
List technical documents are available at:
http://www.si-list.org
List archives are viewable at: =20
http://www.freelists.org/archives/si-list
or at our remote archives:
http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
http://www.qsl.net/wb6tpu
=20
------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
or to administer your membership from a web page, go to:
http://www.freelists.org/webpage/si-list
For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
List FAQ wiki page is located at:
http://si-list.org/wiki/wiki.pl?Si-List_FAQ
List technical documents are available at:
http://www.si-list.org
List archives are viewable at:
http://www.freelists.org/archives/si-list
or at our remote archives:
http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
http://www.qsl.net/wb6tpu
- Follow-Ups:
- [SI-LIST] Re: Selection of Minimum Coupled Length in Cadence SPECCTRAQuest
- From: Ravinder . Ajmani
Other related posts:
- » [SI-LIST] Selection of Minimum Coupled Length in Cadence SPECCTRAQuest
- » [SI-LIST] Re: Selection of Minimum Coupled Length in Cadence SPECCTRAQuest
- » [SI-LIST] Re: Selection of Minimum Coupled Length in Cadence SPECCTRAQuest
- [SI-LIST] Re: Selection of Minimum Coupled Length in Cadence SPECCTRAQuest
- From: Ravinder . Ajmani