If you have just an s11 file, you can configure a 1-port s-parameter
model in HSPICE, and drive it with a pwl and 50 ohm source impedance
through a 50 ohm transmission line. That should give you the correct
reflected waveform.
regards,
Scott
Scott McMorrow
Teraspeed Consulting Group LLC
121 North River Drive
Narragansett, RI 02882
(401) 284-1827 Business
(401) 284-1840 Fax
http://www.teraspeed.com
Teraspeed® is the registered service mark of
Teraspeed Consulting Group LLC
codymiller@xxxxxxxxxx wrote:
> All,
>
> Does anyone in the group know of any available software packages that
> can take post measurement S11 data and convert it to a time domain
> reflected signal?
>
> Thanks,
> Cody Miller
> ------------------------------------------------------------------
> To unsubscribe from si-list:
> si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
>
> or to administer your membership from a web page, go to:
> http://www.freelists.org/webpage/si-list
>
> For help:
> si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
>
>
> List technical documents are available at:
> http://www.si-list.net
>
> List archives are viewable at:
> http://www.freelists.org/archives/si-list
> or at our remote archives:
> http://groups.yahoo.com/group/si-list/messages
> Old (prior to June 6, 2001) list archives are viewable at:
> http://www.qsl.net/wb6tpu
>
>
>
>
------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
or to administer your membership from a web page, go to:
http://www.freelists.org/webpage/si-list
For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
List technical documents are available at:
http://www.si-list.net
List archives are viewable at:
http://www.freelists.org/archives/si-list
or at our remote archives:
http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
http://www.qsl.net/wb6tpu
- References:
- [SI-LIST] internal time step too small error in transient analysis
- From: boli sudha
- [SI-LIST] Re: internal time step too small error in transient analysis
- From: vuk_borich
- [SI-LIST] S parameter to time domain signal
- From: codymiller
Other related posts:
- » [SI-LIST] S parameter to time domain signal
- » [SI-LIST] Re: S parameter to time domain signal
- » [SI-LIST] Re: S parameter to time domain signal
- » [SI-LIST] Re: S parameter to time domain signal
- » [SI-LIST] Re: S parameter to time domain signal
- » [SI-LIST] Re: S parameter to time domain signal
- » [SI-LIST] Re: S parameter to time domain signal
- » [SI-LIST] Re: S parameter to time domain signal
- » [SI-LIST] Re: S parameter to time domain signal
- » [SI-LIST] Re: S parameter to time domain signal
- » [SI-LIST] Re: S parameter to time domain signal
- » [SI-LIST] Re: S parameter to time domain signal
- » [SI-LIST] Re: S parameter to time domain signal
- » [SI-LIST] Re: S parameter to time domain signal
- [SI-LIST] internal time step too small error in transient analysis
- From: boli sudha
- [SI-LIST] Re: internal time step too small error in transient analysis
- From: vuk_borich
- [SI-LIST] S parameter to time domain signal
- From: codymiller