[SI-LIST] Re: S parameter to time domain signal
- From: <Aubrey_Sparkman@xxxxxxxx>
- To: <codymiller@xxxxxxxxxx>, <si-list@xxxxxxxxxxxxx>
- Date: Wed, 19 Dec 2007 13:17:58 -0600
There are several software packages that can do a time domain simulation
with your s11 data, but I'm not aware of any that can directly convert
S11 to a signal. The s11 data represents a response; you will need to
provide the stimulus.
What software do you already have?=20
Aubrey Sparkman=20
Enterprise Engineering Signal Integrity Team=20
Dell, Inc.=20
Aubrey_Sparkman@xxxxxxxx=20
(512) 723-3592=20
"A Measurement for every Model and a Model for every Measurement.
Without Correlation, I don't believe either." - Aubrey Sparkman
-----Original Message-----
From: si-list-bounce@xxxxxxxxxxxxx [mailto:si-list-bounce@xxxxxxxxxxxxx]
On Behalf Of codymiller@xxxxxxxxxx
Sent: Wednesday, December 19, 2007 12:15 PM
To: si-list@xxxxxxxxxxxxx
Subject: [SI-LIST] S parameter to time domain signal
All,
Does anyone in the group know of any available software packages that
can take post measurement S11 data and convert it to a time domain
reflected signal?
Thanks,
Cody Miller
------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
or to administer your membership from a web page, go to:
http://www.freelists.org/webpage/si-list
For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
List technical documents are available at:
http://www.si-list.net
List archives are viewable at: =20
http://www.freelists.org/archives/si-list
or at our remote archives:
http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
http://www.qsl.net/wb6tpu
=20
------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
or to administer your membership from a web page, go to:
http://www.freelists.org/webpage/si-list
For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
List technical documents are available at:
http://www.si-list.net
List archives are viewable at:
http://www.freelists.org/archives/si-list
or at our remote archives:
http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
http://www.qsl.net/wb6tpu
- References:
- [SI-LIST] internal time step too small error in transient analysis
- From: boli sudha
- [SI-LIST] Re: internal time step too small error in transient analysis
- From: vuk_borich
- [SI-LIST] S parameter to time domain signal
- From: codymiller
Other related posts:
- » [SI-LIST] S parameter to time domain signal
- » [SI-LIST] Re: S parameter to time domain signal
- » [SI-LIST] Re: S parameter to time domain signal
- » [SI-LIST] Re: S parameter to time domain signal
- » [SI-LIST] Re: S parameter to time domain signal
- » [SI-LIST] Re: S parameter to time domain signal
- » [SI-LIST] Re: S parameter to time domain signal
- » [SI-LIST] Re: S parameter to time domain signal
- » [SI-LIST] Re: S parameter to time domain signal
- » [SI-LIST] Re: S parameter to time domain signal
- » [SI-LIST] Re: S parameter to time domain signal
- » [SI-LIST] Re: S parameter to time domain signal
- » [SI-LIST] Re: S parameter to time domain signal
- » [SI-LIST] Re: S parameter to time domain signal
- [SI-LIST] internal time step too small error in transient analysis
- From: boli sudha
- [SI-LIST] Re: internal time step too small error in transient analysis
- From: vuk_borich
- [SI-LIST] S parameter to time domain signal
- From: codymiller