[SI-LIST] Re: Pros/Cons of Agilent vs Tek scope for DDR2/3 characterization
- From: Scott McMorrow <scott@xxxxxxxxxxxxx>
- To: Tom Zych <Tom_Zych@xxxxxxxxxxxxxxxxxxx>
- Date: Fri, 17 Apr 2009 11:23:04 -0400
Tom
This posting is blatant advertising. I suggest that next time you
discuss the technical, rather than sales, merits of your software.
regards,
Scott
Tom Zych wrote:
> Eugene -
>
> You may also wish to consider ASA's M1 Oscilloscope Tools. M1 runs on
> Agilent, Tek, LeCroy, and Yokogawa scopes and includes all available
> compliance tests at no additional charge (including DDR2 & DDR3). M1 also
> includes a number of automation and other features specifically designed to
> assist with characterization work.
>
> This combination of features allows you to take the quality of the scope
> manufacturer's compliance test out of the equation of deciding which scope
> to purchase. It also opens up the used/refurbished market (with it's
> considerable cost savings), because M1 will allow you to run your tests on
> *any* compatible scope, regardless of it's age, while the manufacturer's
> software packages will usually only run on their newest models because those
> packages exist solely to help them sell you a really expensive new scope.
> It's just not worth the time for a ScopeCo salesperson with a multi-million
> dollar sales quota to sell you a $3-5,000 software package for a scope you
> already own.
>
> I'd invite you to check out all of M1's features and benefits at our
> website: www.m1ot.com
>
> Regards,
> Tom Zych
> ______________________________
> Tom Zych
> Chief Engineer
> ASA Corp
> phone: +1-413-596-5354
> FAX: +1-413-596-9686
>
>
>
>> From: Eugene Ivanov <eugene.ivanov@xxxxxxx>
>> Date: Fri, 17 Apr 2009 06:07:45 +0200
>> Subject: [SI-LIST] Pros/Cons of Agilent vs Tek scope for
>> DDR2/DDR3 characteriza
>>
>> Need to make a selection of which scope to buy for DDR2/3 i/f
>> JEDEC compliance testing on the memory controller(s). I
>> personally like Tek scope but it is more expensive and its
>> DDR compliance test software doesn't support all the
>> required parameters. Did anybody evaluate both scopes for
>> this application and which one you picked? What were
>> pros/cons to go with Tek vs Agilent or vice versa?
>>
>> Thanks in advance
>>
>
> ------------------------------------------------------------------
> To unsubscribe from si-list:
> si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
>
> or to administer your membership from a web page, go to:
> http://www.freelists.org/webpage/si-list
>
> For help:
> si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
>
>
> List technical documents are available at:
> http://www.si-list.net
>
> List archives are viewable at:
> http://www.freelists.org/archives/si-list
> or at our remote archives:
> http://groups.yahoo.com/group/si-list/messages
> Old (prior to June 6, 2001) list archives are viewable at:
> http://www.qsl.net/wb6tpu
>
>
>
--
Scott McMorrow
Teraspeed Consulting Group LLC
121 North River Drive
Narragansett, RI 02882
(401) 284-1827 Business
(401) 284-1840 Fax
http://www.teraspeed.com
Teraspeed® is the registered service mark of
Teraspeed Consulting Group LLC
------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
or to administer your membership from a web page, go to:
http://www.freelists.org/webpage/si-list
For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
List technical documents are available at:
http://www.si-list.net
List archives are viewable at:
http://www.freelists.org/archives/si-list
or at our remote archives:
http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
http://www.qsl.net/wb6tpu
Other related posts: