[SI-LIST] PSpice to HSpice
- From: nrpatel@xxxxxxxxxxx
- To: si-list@xxxxxxxxxxxxx
- Date: Tue, 29 Nov 2005 11:47:36 -0500
Hi all,
I have a netlist in Pspice that i have converted to an HSpice format.
The Pspice netlist uses the Vswitch option which is not available in
Hspice.
I have modeled the Vswitch as a voltage controlled resistor (VCR) in
Hspice using the G element.
Pspice simulation shows hardly any overshoot or undershoot while the
Hspice simulation shows a lot of overshoot and undershoot.
The only change apart from syntax in both cases is the Vswitch option.
Can anyone suggest if what i am doing is right or is there is a better way
of doing this?
Thanks
Nikhil
------------------------------------------------------------------