[SI-LIST] Re: Message submitted to 'si-list'
- From: Ray Anderson <Raymond.Anderson@xxxxxxx>
- To: si-list@xxxxxxxxxxxxx
- Date: Thu, 25 Jul 2002 10:51:29 -0700 (PDT)
Nancy-
All you need to do is place a large (say 10 Megohm or 100 Megohm)
resistor from node 3 to ground (node 0). This will make Hspice happy
by creating a DC path and not effect the results of your simulation.
I _think_ there is some option you can specify in Hspice to make this
happen automatically, but don't have the details handy at the moment.
-Ray
>
> SI-list,
>
> I am using Star-HSPICE to simulate a very simple circuit, but I got an error
> message "no dc path to ground from node 0:3 ". Can HPICE simulate this
> kind of circuit? How can I fix the error? Thanks.
>
> -----------------circuit script ------------------
> .option post = 2
> .ac lin 100 1e6hz 5ghz
> vs 1 0 ac 1
> rs 2 1 50
> c1 3 2 1e-12
> c2 3 0 2e-12
> .print ac vm(3)
> .end
> ---------------------------------------------------
> **error**: no dc path to ground from node 0:3
>
> Nancy
>
------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
or to administer your membership from a web page, go to:
http://www.freelists.org/webpage/si-list
For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
List archives are viewable at:
http://www.freelists.org/archives/si-list
or at our remote archives:
http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
http://www.qsl.net/wb6tpu
- Follow-Ups:
- [SI-LIST] Re: Message submitted to 'si-list'
- From: Todd Westerhoff
Other related posts:
- » [SI-LIST] Message submitted to 'si-list'
- » [SI-LIST] Re: Message submitted to 'si-list'
- » [SI-LIST] Re: Message submitted to 'si-list'
- [SI-LIST] Re: Message submitted to 'si-list'
- From: Todd Westerhoff