[SI-LIST] Re: Limiting number of nodes in HSPICE .probe output files
- From: Matthew Russell <boomer@xxxxxxxx>
- To: si-list@xxxxxxxxxxxxx
- Date: Mon, 13 May 2002 17:05:36 -0500
I often run into trouble because the probe statement
seems to have a max singal list. So if you want 50 signals
but not 500 it is a problem.
One way to help is to identify subcircuits that you
don't care about and use the
.protect
.unprotect
around them to prevent the nodes inside from showing up
in the trace files.
matt
------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
or to administer your membership from a web page, go to:
http://www.freelists.org/webpage/si-list
For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
List archives are viewable at:
http://www.freelists.org/archives/si-list
or at our remote archives:
http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
http://www.qsl.net/wb6tpu
- References:
- [SI-LIST] Re: Limiting number of nodes in HSPICE .probe output files
- From: Bill . Cohen
Other related posts:
- » [SI-LIST] Limiting number of nodes in HSPICE .probe output files
- » [SI-LIST] Re: Limiting number of nodes in HSPICE .probe output files
- » [SI-LIST] Re: Limiting number of nodes in HSPICE .probe output files
- » [SI-LIST] Re: Limiting number of nodes in HSPICE .probe output files
- » [SI-LIST] Re: Limiting number of nodes in HSPICE .probe output files
- » [SI-LIST] Re: Limiting number of nodes in HSPICE .probe output files
- [SI-LIST] Re: Limiting number of nodes in HSPICE .probe output files
- From: Bill . Cohen