[SI-LIST] Re: [IBIS-Users] IBIS Question

Content-Type: text/plain;
        charset="us-ascii"
Content-Transfer-Encoding: quoted-printable

Hi ,

  =0D

    I have some problem with IBIS model that I had delivered to my
customer. I have attached REPORT file listing all Errors that ICX tool
parsed. There you can find 3 kinds of warnings as follows:

=0D

1) ;;Error :  at line 3991 in file txt05668.ibs : Bad numerical value
52Kohm found.

    This is because in this component few of models using [Rgnd] key
word as follows

=0D

[Rgnd]          52kohm             NA   NA

=0D

i am feeling this Error is because of "ohm" . If I am correct why it is
not showing atleast warning in IBISCHK4 case.

=0D

2) ;;Error :  at line 4438 in file txt05668.ibs : Messages for model
BT0005_MODE0:

;;    ;;    Error: The sum of the typical clamp curves is not monotonic
at voltage 1.78.

;;    ;;    Error: The sum of the maximum clamp curves is not monotonic
at voltage 1.87.

=0D

IBISCHK4 lists as a Non-monotonicity warnings where as ICX listing them
as Errors.=0D

   It would help me lot if you mention how to silence these warnings.=0D

=0D

3) ;;Warning :  at line 5316 in file txt05668.ibs : Pin model
BT0005_MODE0 referred to by the selector BT0005_MODE does not exist in
this file.  Ignoring this selection.

=0D

This I have mentioned Model selector key word option as follows

=0D

[Model Selector]  BT0005_MODE

BT0005_MODE0      Buffer oprating at 1.8V

BT0005_MODE1      Buffer oprating at 2.75V

BT0005_MODE2      Buffer oprating at 3.3V

=0D

As far IBIS since it is proper definition it is not listing where as it
is not recognizing by ICX tool

=0D

Kindly help me by providing proper solution for above problems.=0D

=0D

     Thanks in advance for your valuable support.

=0D

Best Regards

Kiran Kumar

=0D

=0D

      =0D

     =0D

=0D

=0D





Confidentiality Notice=0D

The information contained in this electronic message and any attachments to=
 this message are intended
for the exclusive use of the addressee(s) and may contain confidential or=
 privileged information. If
you are not the intended recipient, please notify the sender at Wipro or=
 Mailadmin@xxxxxxxxx immediately
and destroy all copies of this message and any attachments.


-- Attached file included as plaintext by Ecartis --
-- File: txt05668.report.txt
-- Desc: txt05668.report.txt

;;Error :  at line 3991 in file txt05668.ibs : Bad numerical value 52Kohm found.
;;Error :  at line 4070 in file txt05668.ibs : Bad numerical value 600Kohm 
found.

;;Error :  at line 4438 in file txt05668.ibs : Messages for model BT0005_MODE0:
;;    ;;    Error: The sum of the typical clamp curves is not monotonic at 
voltage 1.78.
;;    ;;    Error: The sum of the maximum clamp curves is not monotonic at 
voltage 1.87.
;;Error :  at line 4653 in file txt05668.ibs : Messages for model BT0005_MODE1:
;;    ;;    Error: The sum of the typical clamp curves is not monotonic at 
voltage 1.78.
;;    ;;    Error: The sum of the maximum clamp curves is not monotonic at 
voltage 1.87.
;;Error :  at line 4868 in file txt05668.ibs : Messages for model BT0005_MODE2:
;;    ;;    Error: The sum of the typical clamp curves is not monotonic at 
voltage 1.78.
;;    ;;    Error: The sum of the maximum clamp curves is not monotonic at 
voltage 1.87.


;;Warning :  at line 5316 in file txt05668.ibs : Pin model BT0005_MODE0 
referred to by the selector BT0005_MODE does not exist in this file.  Ignoring 
this selection.
;;Warning :  at line 5316 in file txt05668.ibs : Pin model BT0005_MODE1 
referred to by the selector BT0005_MODE does not exist in this file.  Ignoring 
this selection.
;;Warning :  at line 5316 in file txt05668.ibs : Pin model BT0005_MODE2 
referred to by the selector BT0005_MODE does not exist in this file.  Ignoring 
this selection.
;;Error :  at line 5316 in file txt05668.ibs : Selector BT0005_MODE does not 
contain any models that were found in this file.
;; Parse failed on file txt05668.ibs.

------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
http://www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field

List FAQ wiki page is located at:
                http://si-list.org/wiki/wiki.pl?Si-List_FAQ

List technical documents are available at:
                http://www.si-list.org

List archives are viewable at:     
                http://www.freelists.org/archives/si-list
or at our remote archives:
                http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu
  

Other related posts: