Hi ,
=0D
I have some problem with IBIS model that I had delivered to my
customer. I have attached REPORT file listing all Errors that ICX tool
parsed. There you can find 3 kinds of warnings as follows:
=0D
1) ;;Error : at line 3991 in file txt05668.ibs : Bad numerical value
52Kohm found.
This is because in this component few of models using [Rgnd] key
word as follows
=0D
[Rgnd] 52kohm NA NA
=0D
i am feeling this Error is because of "ohm" . If I am correct why it is
not showing atleast warning in IBISCHK4 case.
=0D
2) ;;Error : at line 4438 in file txt05668.ibs : Messages for model
BT0005_MODE0:
;; ;; Error: The sum of the typical clamp curves is not monotonic
at voltage 1.78.
;; ;; Error: The sum of the maximum clamp curves is not monotonic
at voltage 1.87.
=0D
IBISCHK4 lists as a Non-monotonicity warnings where as ICX listing them
as Errors.=0D
It would help me lot if you mention how to silence these warnings.=0D
=0D
3) ;;Warning : at line 5316 in file txt05668.ibs : Pin model
BT0005_MODE0 referred to by the selector BT0005_MODE does not exist in
this file. Ignoring this selection.
=0D
This I have mentioned Model selector key word option as follows
=0D
[Model Selector] BT0005_MODE
BT0005_MODE0 Buffer oprating at 1.8V
BT0005_MODE1 Buffer oprating at 2.75V
BT0005_MODE2 Buffer oprating at 3.3V
=0D
As far IBIS since it is proper definition it is not listing where as it
is not recognizing by ICX tool
=0D
Kindly help me by providing proper solution for above problems.=0D
=0D
Thanks in advance for your valuable support.
=0D
Best Regards
Kiran Kumar
=0D
=0D
=0D
=0D
=0D
=0D
Confidentiality Notice=0D
The information contained in this electronic message and any attachments to=
this message are intended
for the exclusive use of the addressee(s) and may contain confidential or=
privileged information. If
you are not the intended recipient, please notify the sender at Wipro or=
Mailadmin@xxxxxxxxx immediately
and destroy all copies of this message and any attachments.
-- Attached file included as plaintext by Ecartis --
-- File: txt05668.report.txt
-- Desc: txt05668.report.txt
;;Error : at line 3991 in file txt05668.ibs : Bad numerical value 52Kohm found.
;;Error : at line 4070 in file txt05668.ibs : Bad numerical value 600Kohm
found.
;;Error : at line 4438 in file txt05668.ibs : Messages for model BT0005_MODE0:
;; ;; Error: The sum of the typical clamp curves is not monotonic at
voltage 1.78.
;; ;; Error: The sum of the maximum clamp curves is not monotonic at
voltage 1.87.
;;Error : at line 4653 in file txt05668.ibs : Messages for model BT0005_MODE1:
;; ;; Error: The sum of the typical clamp curves is not monotonic at
voltage 1.78.
;; ;; Error: The sum of the maximum clamp curves is not monotonic at
voltage 1.87.
;;Error : at line 4868 in file txt05668.ibs : Messages for model BT0005_MODE2:
;; ;; Error: The sum of the typical clamp curves is not monotonic at
voltage 1.78.
;; ;; Error: The sum of the maximum clamp curves is not monotonic at
voltage 1.87.
;;Warning : at line 5316 in file txt05668.ibs : Pin model BT0005_MODE0
referred to by the selector BT0005_MODE does not exist in this file. Ignoring
this selection.
;;Warning : at line 5316 in file txt05668.ibs : Pin model BT0005_MODE1
referred to by the selector BT0005_MODE does not exist in this file. Ignoring
this selection.
;;Warning : at line 5316 in file txt05668.ibs : Pin model BT0005_MODE2
referred to by the selector BT0005_MODE does not exist in this file. Ignoring
this selection.
;;Error : at line 5316 in file txt05668.ibs : Selector BT0005_MODE does not
contain any models that were found in this file.
;; Parse failed on file txt05668.ibs.
------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
or to administer your membership from a web page, go to:
http://www.freelists.org/webpage/si-list
For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
List FAQ wiki page is located at:
http://si-list.org/wiki/wiki.pl?Si-List_FAQ
List technical documents are available at:
http://www.si-list.org
List archives are viewable at:
http://www.freelists.org/archives/si-list
or at our remote archives:
http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
http://www.qsl.net/wb6tpu
Other related posts:
- » [SI-LIST] Re: [IBIS-Users] IBIS Question