[SI-LIST] IBIS Model error

  • From: "Suresh.K" <sureshk@xxxxxxxxxxxxxx>
  • To: si-list@xxxxxxxxxxxxx
  • Date: Mon, 17 Nov 2003 14:37:21 +0500 (GMT+0500)

Hi Gurus,

Warm Wishes to all ......

I'm a beginner for SI Analysis and I need some clarification
about the Error of IBIS Model(71V2546-SRAM),which I'm getting when I
Import it into the Zuken's Hotstage tool Constraint Manager-Simulation 
Library.

Actully I'm using the model ,which I downloaded from IDT website.

Please look into the error message below and give your precious
suggestions,

ERROR- Model IOPAD2546Z: The [Rising Waveform] 
with [R_fixture]=50 Ohms and [V_fixture]=1.5V
has TYP column DC endpoints of  0.50V and  2.21v, but
an equivalent load applied to the model's I-V tables yields
different voltages ( 2.13V and  2.69V),
a difference of 288.80% and 84.70%, respectively.
ERROR- Model IOPAD2546Z: The [Falling Waveform] 
with [R_fixture]=50 Ohms and [V_fixture]=1.5V
has TYP column DC endpoints of  0.50V and  2.21v, but
an equivalent load applied to the model's I-V tables yields
different voltages ( 2.13V and  2.69V),
a difference of 288.98% and 84.70%, respectively.
WARNING- Model 'IOPAD2546Z': TYP VI curves cannot drive through
Vmeas=1.25V
          given load Rref=50 Ohms to Vref=1.5V
ERROR- Model IOPAD2546Z: The [Rising Waveform] 
with [R_fixture]=50 Ohms and [V_fixture_min]=1.5V
has MIN column DC endpoints of  0.53V and  2.11v, but
an equivalent load applied to the model's I-V tables yields
different voltages ( 2.04V and  2.54V),
a difference of 304.74% and 86.47%, respectively.
ERROR- Model IOPAD2546Z: The [Falling Waveform] 
with [R_fixture]=50 Ohms and [V_fixture_min]=1.5V
has MIN column DC endpoints of  0.53V and  2.11v, but
an equivalent load applied to the model's I-V tables yields
different voltages ( 2.04V and  2.54V),
a difference of 304.74% and 86.47%, respectively.
WARNING- Model 'IOPAD2546Z': MIN VI curves cannot drive through
Vmeas=1.25V
          given load Rref=50 Ohms to Vref=1.5V
ERROR- Model IOPAD2546Z: The [Rising Waveform] 
with [R_fixture]=50 Ohms and [V_fixture_max]=1.5V
has MAX column DC endpoints of  0.48V and  2.32v, but
an equivalent load applied to the model's I-V tables yields
different voltages ( 2.22V and  2.83V),
a difference of 283.59% and 82.91%, respectively.
ERROR- Model IOPAD2546Z: The [Falling Waveform] 
with [R_fixture]=50 Ohms and [V_fixture_max]=1.5V
has MAX column DC endpoints of  0.48V and  2.32v, but
an equivalent load applied to the model's I-V tables yields
different voltages ( 2.22V and  2.83V),
a difference of 283.59% and 82.74%, respectively.
WARNING- Model 'IOPAD2546Z': MAX VI curves cannot drive through
Vmeas=1.25V
          given load Rref=50 Ohms to Vref=1.5V
Errors  : 6
Warnings: 6

File Failed

Thanks & Regards,
Suresh.K,
Vth EDA Lab,
C-DOT,
Bangalore-52.

------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field

List technical documents are available at:
                http:/www.si-list.org

List archives are viewable at:     
                //www.freelists.org/archives/si-list
or at our remote archives:
                http://groups.yahoo.com/group/si-list/messages 
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu
  

Other related posts: