[SI-LIST] Re: IBIS Model Quality (or lack thereof)


On Mar 26, "Todd Westerhoff" <twester@xxxxxxxxxxx> wrote:
> 
> We're currently using two "standard" text fixtures to compare IBIS/HSpice
> models:
> 
> * I/O buffer connected to VDDQ/2 through 50 ohms
> * I/O buffer connected to 0.5ns, 50ohm tline, 5pf to GND at tline end

Do you use HSPICE simulator for both simulations (with IBIS and HSPICE models), 
or you 
use some other simulator with the IBIS model? The reason I ask, I think not all 
simulators have the same way of handling IBIS models. In one case, I used an 
IBIS model 
of a true differential CML driver with no problems in SPECCTRAQuest but the 
model failed 
to run in HSPICE. 

As to your first test fixture, I'd recommend using a load other than 50ohm. 
Some IBIS 
models work fine when terminated with 50ohms but break for any other loads. 
This has 
something to do with the way the models were generated.
 
Regards.

Hassan.
------------------------------------------------------------------