[SI-LIST] Re: Hspice B element

  • From: "Ingraham, Andrew" <Andrew.Ingraham@xxxxxxxxxx>
  • To: <si-list@xxxxxxxxxxxxx>
  • Date: Fri, 25 Jan 2002 08:18:04 -0500

>                             ---------------
>                          *
>                       *
>                     *
> -----------------
> for the hspice output and
>=20
>                            --------------
>                          *
>                          *
>                          *
> ------------------------
> for the IBIS output.
>=20
> What could I be doing wrong here? Any inputs will be appreciated.
>=20
>=20
Some things to check:

Is the B-element connected correctly?  Are you using the right B-element
node for connection to the rest of your circuit?

What is the load?

Double-check the units in the IBIS datasheet file ("model").

Is the risetime the only difference, or are the initial and final
voltage levels wrong too?

Regards,
Andy


------------------------------------------------------------------