[SI-LIST] How to connect vias to power ground plane?

  • From: Zhangkun <zhang_kun@xxxxxxxxxx>
  • To: si-list <si-list@xxxxxxxxxxxxx>
  • Date: Thu, 19 Dec 2002 08:50:55 +0800

Hi all:

In PCB, which method to connect vias to power ground plane do you favour, 
full-connected or orthogonal-connected? I think full-connected will be better 
for less resistance and less inductance. Recently I have done some simulation 
by means of Ansoft. The result surprised me. The inductance and resistance of 
orthogonal-connected mode is less than that of full-connected mode.

If anyone are interesting of my simulation result, please inform me. I will 
send it to him. Si-list does not permit to add attachment.

Best Regards
Zhangkun