[SI-LIST] How to connect vias to power ground plane?
- From: Zhangkun <zhang_kun@xxxxxxxxxx>
- To: si-list <si-list@xxxxxxxxxxxxx>
- Date: Thu, 19 Dec 2002 08:50:55 +0800
Hi all:
In PCB, which method to connect vias to power ground plane do you favour,
full-connected or orthogonal-connected? I think full-connected will be better
for less resistance and less inductance. Recently I have done some simulation
by means of Ansoft. The result surprised me. The inductance and resistance of
orthogonal-connected mode is less than that of full-connected mode.
If anyone are interesting of my simulation result, please inform me. I will
send it to him. Si-list does not permit to add attachment.
Best Regards
Zhangkun
2002.12.19
------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
or to administer your membership from a web page, go to:
http://www.freelists.org/webpage/si-list