[SI-LIST] Re: How to attach a 5 mil trace to a 603 component pad?

> I require that this trace be AC coupled between the source and the
> load. The pads on a 603 package look like football fields compared to
> the trace. This must cause a discontinuity.

If the discontinuity of this scale is important in your application (I guess
depends on the frequency you operate at) then you should consider using
smaller parts such as 0402 or even 0201.

/Mikhail


------------------------------------------------------------------