[SI-LIST] Re: GTL buffers Vref

  • From: Samuel Dadel <samuel_dadel@xxxxxxxxx>
  • To: si-list@xxxxxxxxxxxxx
  • Date: Fri, 30 Aug 2002 13:13:45 -0700 (PDT)

Hi,

We are faced with a similar situation. The Vref nominal is 1.0 Volts, and

upto a certain transition density on the receivers works fine[we have

source synchronous interfaces]. We take it to x-23 PRBS and we start

detecting bit errors. Altering Vref at this point to 0.8 Volts brings down

the bit error level to a reasonable and acceptable level. Someone in the list

suggested high-side ringback? Could that be susceptible to data-transition

density?

 

--Sam

 



---------------------------------