Perry.
Check out Tensolite Accuphase. It works to 40ghz last I heard. They make cables
for testing products with 35ps TDR test equipment. We did a test box for 65
channel cable product and used this cable in the test unit and it did a fine
job up to 35ps.
Tensolite is now Carlisle Interconnect Technologies. They make probes and
cables for Tektronix, Agilent and Boeing so its good quality stuff.
http://www.tensolite.com/v2/index.asp
Good luck
Richard Jungert
> Subject: [SI-LIST] Re: SMA cable for TDR
> Date: Tue, 28 Oct 2008 16:16:16 -0500
> From: Perry.Qu@xxxxxxxxxxxxxxxxxx
> To: weirsi@xxxxxxxxxx; zabinski.patrick@xxxxxxxx; Mark.Randol@xxxxxxxxxx;
> Chris.Cheng@xxxxxxxx
> CC: si-list@xxxxxxxxxxxxx
>
> Thanks everyone for the suggestions on/off list. I had quite a few leads
> to pursue.
>
> I'm not looking for super high bandwidth cable, but it needs to be
> better than the cheap blue semi-rigid cable I'm using now. It's a pain
> to try to find some matching cables (I have seen some terrible mismatch
> in delay and attenuation even though they all measured 3 feet). I'm
> also concerned about bend radius and the impact on measurement
> consistency.
>
> Steve/Chris: I did search for Gore cable on Ebay and there are some nice
> cables out there, just did not find anything that suit my needs. :)
>
> Pat: agree that good quality cable is important together with good
> calibration practice for model extraction purpose. I have seen the
> impact of these factors on my measurement results.
>
> Mark: thanks for the 3.5mm suggestions. That's also recommended by Gore
> engineer.
>
> Regards
>
> Perry
>
> =======================================
>
> Perry Qu
>
> Design & Qualification, Alcatel-Lucent Canada Inc.
>
> 600 March Road, Ottawa ON, K2K 2E6, Canada
>
> DID: 613-7846720 Fax: 613-5993642
>
> Email: perry.qu@xxxxxxxxxxxxxxxxxx
>
> =======================================
> ------------------------------------------------------------------
> To unsubscribe from si-list:
> si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
>
> or to administer your membership from a web page, go to:
> http://www.freelists.org/webpage/si-list
>
> For help:
> si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
>
>
> List technical documents are available at:
> http://www.si-list.net
>
> List archives are viewable at:
> http://www.freelists.org/archives/si-list
> or at our remote archives:
> http://groups.yahoo.com/group/si-list/messages
> Old (prior to June 6, 2001) list archives are viewable at:
> http://www.qsl.net/wb6tpu
>
>
Store, manage and share up to 5GB with Windows Live SkyDrive. Start uploading
now
_________________________________________________________________
You live life beyond your PC. So now Windows goes beyond your PC.
http://clk.atdmt.com/MRT/go/115298556/direct/01/
------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
or to administer your membership from a web page, go to:
http://www.freelists.org/webpage/si-list
For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
List technical documents are available at:
http://www.si-list.net
List archives are viewable at:
http://www.freelists.org/archives/si-list
or at our remote archives:
http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
http://www.qsl.net/wb6tpu
- References:
- [SI-LIST] SMA cable for TDR
- From: QU Perry
- [SI-LIST] Re: SMA cable for TDR
- From: QU Perry
Other related posts:
- » [SI-LIST] FW: Re: SMA cable for TDR
- [SI-LIST] SMA cable for TDR
- From: QU Perry
- [SI-LIST] Re: SMA cable for TDR
- From: QU Perry