[SI-LIST] EMC test
- From: "Bleu, Carlo" <Carlo_Bleu@xxxxxxxxxxxxxxxxx>
- To: <si-list@xxxxxxxxxxxxx>
- Date: Mon, 28 Nov 2005 10:06:41 +0100
Hi gurus,
I have some question about the setup test for EN55022.
My product is a cpe that has some lan interface 10/100baseT, an aDSL
port and a WiFi access point. I have to perform test compliance to the
ETSI 301-489-1 and 301-489-17 for the WiFi part, and the EN55022 for all
device parts.
My question is about the EN55022 setup, when I measure the emission in
semi-anechoic chamber I have to put some device (i. e. a pc) in the
chamber to ensure that there is traffic on the WiFi link, or it is not
necessary and I have only the link up, since I've done the ETSI test?
Obviously all other ports are connected to devices that are not in the
chamber.
Any suggestion is very appreciated.
Thanks a lot
Carlo
Carlo Bleu
---------------------------------------
Hardware Design Engineer
Allied Telesis Multimedia S.r.l.
P.zza Tirana 24/4B - 20147 Milano MI - Italy
Office +39 02 41304306 (ext. 306)
Fax +39 02 41304351
------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
or to administer your membership from a web page, go to:
http://www.freelists.org/webpage/si-list
For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
List FAQ wiki page is located at:
http://si-list.org/wiki/wiki.pl?Si-List_FAQ
List technical documents are available at:
http://www.si-list.org
List archives are viewable at:
http://www.freelists.org/archives/si-list
or at our remote archives:
http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
http://www.qsl.net/wb6tpu
Other related posts: