[SI-LIST] Re: Diode in test load
- From: Virendra <adsurevv@xxxxxxxxx>
- To: tom@xxxxxxxxxxxxx
- Date: Wed, 20 Nov 2002 15:11:06 -0800 (PST)
i am sorry, there is only one diode....the test
circuit is in the spec. sheet so i need to put it in
the IBIS model.
--- Tom Dagostino <tom@xxxxxxxxxxxxx> wrote:
> In your circuit I'm surprised if diodes (I see two
> of them) and the R have
> any effect at all. To get meaningful current in the
> diodes they need to be
> forward biased, have about 0.6 or 0.7 volts across
> them. With a 1.3 Volt
> supply I don't see how they are going to conduct
> unless they are very low
> forward voltage devices. Drop the R and diodes and
> just put in the C.
>
>
> Tom Dagostino
> Device Modeling Division
> Teraspeed Consulting Group LLC
> 2926 SE Yamhill St.
> Portland, OR 97214
> (503) 430-1065
> tom@xxxxxxxxxxxxx
> http://www.teraspeed.com
>
>
> -----Original Message-----
> From: si-list-bounce@xxxxxxxxxxxxx
> [mailto:si-list-bounce@xxxxxxxxxxxxx]On Behalf Of
> Virendra
> Sent: Wednesday, November 20, 2002 2:00 PM
> To: si-list@xxxxxxxxxxxxx
> Subject: [SI-LIST] Diode in test load
>
>
>
> Hello all,
> Can someone pl. tell me how i can incorporate a
> diode
> in the test load of an IBIS model. I am trying to
> draw
> a picture of the test setup below. The diode is in
> series with the RL.
>
>
> -----1.3V
> |
> |
> ---
> Diode
> ---
> |
> |
> ____
> Diode
> ----
> |
> ____
> Rl
> ____
> |
>
> DUT --------|--------------OUT
> |
> ____
> Cl
> ----
> |
> |
> ----GND
>
> Thanks in advance,
>
> Virendra
>
> Virendra Adsure
> viru@xxxxxxxx
>
>
> __________________________________________________
> Do you Yahoo!?
> Yahoo! Web Hosting - Let the expert host your site
> http://webhosting.yahoo.com
>
------------------------------------------------------------------
> To unsubscribe from si-list:
> si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in
> the Subject field
>
> or to administer your membership from a web page, go
> to:
> http://www.freelists.org/webpage/si-list
>
> For help:
> si-list-request@xxxxxxxxxxxxx with 'help' in the
> Subject field
>
> List archives are viewable at:
> http://www.freelists.org/archives/si-list
> or at our remote archives:
> http://groups.yahoo.com/group/si-list/messages
> Old (prior to June 6, 2001) list archives are
> viewable at:
> http://www.qsl.net/wb6tpu
>
>
__________________________________________________
Do you Yahoo!?
Yahoo! Web Hosting - Let the expert host your site
http://webhosting.yahoo.com
------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
or to administer your membership from a web page, go to:
http://www.freelists.org/webpage/si-list
For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
List archives are viewable at:
http://www.freelists.org/archives/si-list
or at our remote archives:
http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
http://www.qsl.net/wb6tpu
- Follow-Ups:
- [SI-LIST] Re: Diode in test load
- From: Tom Dagostino
Other related posts:
- » [SI-LIST] Diode in test load
- » [SI-LIST] Re: Diode in test load
- » [SI-LIST] Re: Diode in test load
- [SI-LIST] Re: Diode in test load
- From: Tom Dagostino