Dear Mahesh,

Series termination is the most common selection for a point-to-point
topology.

When the bus is unidirectional, the ideal placement for the source
terminator is close to
the driver. For series termination of a bidirectional bus two resistors may
be required
(one near each agent) or just a single resistor some where in the middle of
the line.

There exist rules of thumb and mathematical formulas for determining the
effective 
locations and values for series terminators. However, the need for and the
optimum 
termination solution is usually ascertained with aid of simulation. 
 
Best Regards,

Abe Riazi
ServerWorks

-----Original Message-----
From: si-list-bounce@xxxxxxxxxxxxx [mailto:si-list-bounce@xxxxxxxxxxxxx] On
Behalf Of mahesh.linge@xxxxxxxxx
Sent: Wednesday, June 29, 2005 12:32 AM
To: si-list@xxxxxxxxxxxxx
Subject: [SI-LIST] Data Bus termination



Hi,
I have Processor Flash and SDRAM on my board.My data bus is running at 125
MHz.I would like to know placement of the series termination resistors on
the data bus as it will be a bisectional.

Thanks in advance.

Regards,
Mahesh


 


------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
http://www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field

List FAQ wiki page is located at:
                http://si-list.org/wiki/wiki.pl?Si-List_FAQ

List technical documents are available at:
                http://www.si-list.org

List archives are viewable at:     
                http://www.freelists.org/archives/si-list
or at our remote archives:
                http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu
  

Other related posts: