[SI-LIST] 1 oz vs. 1/2 oz cu
- From: "Inchauspe, Greg E" <greg.e.inchauspe@xxxxxxxx>
- To: Sig Integ Group <si-list@xxxxxxxxxxxxx>
- Date: Tue, 27 Apr 2004 09:39:22 -0700
Hello SI,
I'm working on a 18 layer board stack-up and was wondering what the =
trade-offs are between going with 1 oz Cu signal layers and =BD oz Cu =
signal layers. All power and ground are 1 oz Cu.
Thanks,
Greg
------------------------------------------------------------------