[rodgersorgan] Re: Expression shoe and MIDI playback with PR 300-S

I have played a couple of recitals on 837s, and I regularly play a 957 in a 
chapel and a 927 at my church.  I have run into this on all of these 
instruments when playing the organ along with orchestral sequences such as 
Hector's hymn paraphrases.  The expression shoe should NOT affect the volume 
of PR-300 voices under normal circumstances.  However, I found that if I had 
engaged the Gt. MIDI A piston to play PR-300 voices in real time and then 
tried to play the organ with an orchestral sequence, the PR-300 voices in the 
sequence would then be controlled by the expression shoe.  I found myself 
powering down the organ and PR-300, and then powering back up again.  This 
would "re-set" everything and then I could play the pieces with orchestral 
sequences so that only the organ and not the PR-300 would be affected by the 
expression shoe.

In discussing this with Dan Miller, I learned that this is a software issue 
and there is a fix.  I have had the upgrade done to my 957 and it has worked 
perfectly since.  I will have my dealer do the same to my 927.  The upgrade 
is available through your local Rodgers dealer.

Hope this helps.

Jay Brooks
Wilmington, NC



Other related posts: