[pure-silver] Re: HC 110 question ...
- From: "bill harting" <vintagebill@xxxxxxxxxxx>
- To: <pure-silver@xxxxxxxxxxxxx>
- Date: Wed, 31 May 2006 15:02:17 -0400
I also use a narrow Jobo 2 ounce graduated cylinder with metric markings,
and usually use Dil. H, sometimes Dil.E, occasionally Dil B, and have had no
trouble with consistent results for either half-liter and full liter
stainless film cannisters.
bill h
----- Original Message -----
From: "Koch, Gerald" <gkoch02@xxxxxxxxxx>
To: <pure-silver@xxxxxxxxxxxxx>
Sent: Tuesday, May 30, 2006 12:59 PM
Subject: [pure-silver] Re: HC 110 question ...
I have no problems measuring HC-110 concentrate using a polyethylene 10
ml graduated cylinder. The only thing that is a bit unusual is that
there is little or no meniscus. I dilute 1:50 for convenience and use
the times recommended for dilution H (2X dilution B).
The diluted stock solution has limited keeping properties while the
concentrate is eternal. I forget Kodak's recomendation, 3 months for
partially filled bottles?
Jerry
====================================To unsubscribe from this list, go to
www.freelists.org and logon to your account (the same e-mail address and
password you set-up when you subscribed,) and unsubscribe from there.
=============================================================================================================
To unsubscribe from this list, go to www.freelists.org and logon to your
account (the same e-mail address and password you set-up when you subscribed,)
and unsubscribe from there.
- Follow-Ups:
- [pure-silver] Re: HC 110 question ...
- From: tOM Trottier
- References:
- [pure-silver] Re: HC 110 question ...
- From: Koch, Gerald
Other related posts:
- » [pure-silver] HC 110 question ...
- » [pure-silver] Re: HC 110 question ...
- » [pure-silver] Re: HC 110 question ...
- » [pure-silver] Re: HC 110 question ...
- » [pure-silver] Re: HC 110 question ...
- » [pure-silver] Re: HC 110 question ...
- » [pure-silver] Re: HC 110 question ...
- » [pure-silver] Re: HC 110 question ...
- » [pure-silver] Re: HC 110 question ...
- » [pure-silver] Re: HC 110 question ...
- » [pure-silver] Re: HC 110 question ...
- » [pure-silver] Re: HC 110 question ...
- » [pure-silver] Re: HC 110 question ...
- » [pure-silver] Re: HC 110 question ...
- » [pure-silver] Re: HC 110 question ...
I have no problems measuring HC-110 concentrate using a polyethylene 10 ml graduated cylinder. The only thing that is a bit unusual is that there is little or no meniscus. I dilute 1:50 for convenience and use the times recommended for dilution H (2X dilution B).
- [pure-silver] Re: HC 110 question ...
- From: tOM Trottier
- [pure-silver] Re: HC 110 question ...
- From: Koch, Gerald