Re: streams capture specify SCN without dbms_cature_adm.build

  • From: Alex Fatkulin <afatkulin@xxxxxxxxx>
  • To: Upendra N <nupendra@xxxxxxxxxxx>
  • Date: Fri, 8 Apr 2011 10:28:52 -0400

You do realize he won't be able to run the Capture process without
executing the dictionary build first?

This has nothing to do wit apply.

On Fri, Apr 8, 2011 at 9:53 AM, Upendra N <nupendra@xxxxxxxxxxx> wrote:
> It is not necessary that you run the dictionary build procedure as long as
> there aren't any schema changes.
>

-- 
Alex Fatkulin,
http://afatkulin.blogspot.com
http://www.linkedin.com/in/alexfatkulin
--
//www.freelists.org/webpage/oracle-l


Other related posts: