Re: data guard fast start failover

  • From: Alex Gorbachev <ag@xxxxxxxxxxxx>
  • To: strickland.mark@xxxxxxxxx
  • Date: Mon, 19 Jan 2009 08:49:17 +1100

Hi Mark,

Could you elaborate on WebLogic config you are using for RAC?
- Is it configured using WebLogic multi-datasources?
- Do you use WebLogic XA transactions? Does WebLogic datasource re- tries transaction on reconnect? - What are the patched you mentioned (perhaps, you have the reference to the WebLogic support docs)?

Cheers,
Alex

On 17/01/2009, at 8:52 AM, Mark Strickland wrote:

We've been testing FSF with 10.2.0.2 and my co-DBA discovered a bug that can cause a split-brain to occur. I don't remember the exact circumstances, but the fix is in 10.2.0.4 which is driving us to apply that patchset. Our FSF testing with 10.2.0.4 has been going very well. If you use WebLogic, it will handle a failover but it requires a patch depending on what version you use. I've been doing new 10.2.0.4 builds with RAC and Data Guard with FSF for a new customer. No issues so far.

Mark
Seattle, WA


On Thu, Jan 15, 2009 at 11:27 PM, <Laimutis.Nedzinskas@xxxxxx> wrote:

Hi all

Anyone's using data guard fast-start failover ?
What are the experiences ?
What about split brain?
Does it interfere heavily with normal database activities?
Any other comments?

Thank you in advance,

Laimis N

--