Re: Split Brains - Not another Boy Band

Thanks to all those who replied.

The interconnect is a dedicated ethernet network. 2 cards. 1 Gig bandwidth.

The lmd and lms trace files show the reason for eviction as "reason code
3", which indicates a communication failure, across the interconnect.

There are other 2 RAC instances on the same nodes, which did not suffer
from this split brain. So, that would rule out any time synchonization, or
high resource utilization, wouldn't it?

Anyways, have opened a TAR with OWS.

Thanks
Raj




                                                                                
                                                        
                      Jared Still                                               
                                                        
                      <jkstill@xxxxxxxxx        To:       
Rajesh.Rao@xxxxxxxxxxxx                                                       
                      >                         cc:       
Oracle-L@xxxxxxxxxxxxx                                                        
                      Sent by:                  Subject:  Re: Split Brains - 
Not another Boy Band                                       
                      oracle-l-bounce@fr                                        
                                                        
                      eelists.org                                               
                                                        
                                                                                
                                                        
                                                                                
                                                        
                      03/03/2005 06:28                                          
                                                        
                      PM                                                        
                                                        
                      Please respond to                                         
                                                        
                      jkstill                                                   
                                                        
                                                                                
                                                        
                                                                                
                                                        




Is the interconnect a dedicated network?


On Thu, 3 Mar 2005 17:10:29 -0500, Rajesh.Rao@xxxxxxxxxxxx
<Rajesh.Rao@xxxxxxxxxxxx> wrote:
> Hello All, Not being much of an SA, are they any specific OS or Cluster
> logfiles that I can look for, to determine the cause of one node being
> evicted in a two node cluster (9.2.0.5.0 RAC on Solaris 5.8 and Sun
Cluster
> 3.0), due to a split brain. The eviction happened due to "reason 3",
which
> would indicate a communication failure, across the interconnect. Nothing
in
> /var/adm/messages or syslog. We suspect there was heavy resource
> utilization on one of the nodes, which could have caused it.
>
> Thanks
> Raj
>
> --
> http://www.freelists.org/webpage/oracle-l
>


--
Jared Still
Certifiable Oracle DBA and Part Time Perl Evangelist
--
http://www.freelists.org/webpage/oracle-l



--
http://www.freelists.org/webpage/oracle-l

Other related posts: