I have a job in OEM that failed while trying to create a physical standby on
another server. I know the reason, port 3872 blocked between 2 servers. I'll
submit the firewall request, but in the meantime I'd really like to figure out
exactly where OEM failed and complete the standby creation manually. I see
info in the logs in OEM and in sysman.mgmt$job_step_history, but this does not
include the code OEM generated to create the standby. Where can that be found?
Just trying to save some time in creating the standby manually (although I'm
sure I've already wasted that time looking for answers...).
OEM 13.2, Oracle DB 11.2.0.4
Thanks,
Steve